Description
The Gianneschi VCP is the forward-curved heavy-duty centrifugal marine blower — the high-flow choice for engine-room ventilation and harmful-gas extraction. Forward-curved blades move large volumes of air at medium pressure with low noise, making the VCP the workhorse where flow matters more than static pressure. Built for yachts and commercial vessels.
Key features of the Gianneschi VCP
- Forward-curved steel impeller — high air-flow at medium pressure, low noise
- Steel spiral (scroll) casing; stainless casing / impeller on request
- Handles clean or slightly dusty air up to 80 °C; suited to harmful-gas extraction
- Voltages: 12–24 V DC; 230 V 1~ 50 Hz / 208–240 V 1~ 60 Hz; 230/400 V 3~ 50 Hz / 208–240 / 360–400 V 3~ 60 Hz
- Class F insulation; IP22 (DC) / IP44–55 (AC)
- No-spark / ATEX motor option for fuel-vapour zones
- Models VCP 161, 201, 221, 251, 281, 311, 351, 401, 451 (indicative — confirm current range at quote)
Typical Superyacht Applications
- Heavy-duty engine-room supply / extraction where high air-flow is the priority
- Galley / kitchen-hood and toilet extraction on moderate duct runs
- Technical rooms and harmful-gas removal
Model line-up
VCP frames rise in size and connection diameter from the compact 161 to the 451, and most are offered in several motor / speed variants (930–2800 rpm). The smaller frames (161–251) include high-speed 2800 rpm builds that push very high free-air flow at low-to-medium pressure, while the larger frames (281–451) run slower and are built to hold higher pressure. So the max delivery below — indicative free-air figures from the factory datasheet (Ed. 10/2009) — does not simply climb with frame size; choose by your actual flow-and-pressure duty and confirm at quote.
| Model | Motor (kW)1 | Speed (rpm) | Connection Ø | Max delivery2 |
|---|---|---|---|---|
| VCP 161 | 0.25 | 2800 | 145 mm | ~60 m³/min |
| VCP 201 | 0.25–1.1 | 1450–2800 | 205 mm | ~120 m³/min |
| VCP 221 | 0.37–2.2 | 1450–2800 | 229 mm | ~163 m³/min |
| VCP 251 | 0.55–4.0 | 1450–2800 | 255 mm | ~210 m³/min |
| VCP 281 | 0.75 | 1450 | 286 mm | ~62 m³/min |
| VCP 311 | 0.37–1.5 | 930–1450 | 321 mm | ~82 m³/min |
| VCP 351 | 0.75–3.0 | 930–1450 | 361 mm | ~108 m³/min |
| VCP 401 | 1.5–7.5 | 930–1450 | 406 mm | ~148 m³/min |
| VCP 451 | 3.0–7.5 | 930–1450 | 456 mm | ~175 m³/min |
1 Installed-power range across the frame’s motor / speed variants (12–24 V DC and 1~/3~ AC available). 2 Indicative free-air delivery; delivery falls as duct pressure rises. Backward-curved VCR reaches higher pressure and delivery again. Confirm duty at quote.
Configuration options
- Model — the frame size; sets airflow and pressure.
- Power Supply — 12/24 V DC or single/three-phase AC, 50 or 60 Hz (at 60 Hz the AC options run in the 208–240 V band).
- Motor — Standard, or No-spark / ATEX Ex-rated for spaces where fuel vapour or an explosive atmosphere may be present.
- Impeller Material — steel (standard) or stainless steel for greater corrosion resistance.
- Mounting — wall (bulkhead), roof / deckhead, or in-line within a duct run — pick to suit where the blower sits.
Installation & Compatibility Notes
- Configure-to-order: specify model, size, duty (m³/min @ mmH₂O), voltage/phase/Hz, mounting (wall / roof / in-line), motor type and impeller material
- Facing higher back-pressure or long, restrictive runs? Choose the backward-curved Gianneschi VCR. For lighter standard-duty extraction, the C series is the compact alternative.
- Pair with the Gianneschi Control Fan (G-Touch) VFD system for variable-speed control; add silencers / anti-vibration rings as needed