The Gianneschi marine smoke damper is a remotely-actuated ventilation shut-off and smoke-control damper — operated on command (manual, pneumatic or electric actuator), not automatically by heat. Its job is to control where air and smoke go: close ventilation to a space, isolate a compartment, or contain and route smoke away from escape routes.
How the marine smoke damper differs from a fire damper
A fire damper is passive and automatic — it closes on a heat trigger to seal an A-class fire boundary. A smoke damper is active and driven by an actuator — the crew or the ventilation-shutdown system closes it deliberately. They are complementary, not alternatives, and are usually specified together.
Why fit a smoke damper
- Emergency ventilation shut-off — the means to stop fans and close ventilation to a space from outside it (e.g. starving an engine-room fire of air before releasing fixed fire-fighting)
- Smoke containment / extraction — keeping smoke out of accommodation and escape routes, or routing it out
- Compartment isolation on command
Key Features
- Drives available: manual, pneumatic or electric actuator
- Stainless-steel construction; white-painted optional
- Wide range with customised dimensions
Typical Superyacht Applications
- Engine-room and technical-room ventilation shut-off arrangements
- Galley / kitchen-hood ductwork smoke control
Configuration options
- Actuator — Manual, Pneumatic or Electric — how the damper is driven for remote ventilation shut-off.
- Finish — stainless steel or white-painted.
- Nominal Size — Ø215–1000 mm; match to the connecting duct / blower diameter.
Installation & Compatibility Notes
- Part of the vessel’s ventilation shut-off / smoke-management arrangement; specify size, actuator type and orientation
- Use alongside the Gianneschi fire damper — the fire damper gives automatic boundary fire-sealing, the smoke damper gives commanded shut-off / smoke control