Description
The FCI Tap Water (Dockwater) Membrane (SKU 10-1623) is the genuine OEM reverse osmosis membrane element for the dockwater circuit on FCI APC/DTS watermakers. When connected to a shore water supply, the APC/DTS system switches into dockwater mode and passes the pressurised marina feed through this membrane to produce purified, spot-free water for vessel use. The membrane operates at low feed pressures (25–50 PSI) without a high-pressure pump, relying on the Automatic Pressure Control (APC) valve to optimise output for conditions. A fresh, correctly specified membrane is critical to dockwater mode performance — a degraded element reduces output quality and volume, defeating the purpose of the shore connection. Available from Y3 Marine as a special order — contact us for pricing and lead time.
Key Features
- Genuine FCI OEM tap water RO membrane — SKU 10-1623, correct specification for all APC/DTS dockwater circuits
- Standard 4″ × 40″ spiral-wound membrane element in a 300 PSI rated FRP pressure vessel
- Designed for low-pressure dockwater operation — feed pressure 25–50 PSI, no high-pressure pump required
- APC valve automatically adjusts to maintain output quality regardless of varying shore water pressure
- Upstream GAC carbon filter removes chlorine from the shore supply before it reaches the membrane
- Compatible across all FCI models equipped with a dockwater pressure vessel assembly
- Available as a special order through Y3 Marine, Australia’s authorised FCI dealer
Typical Superyacht Applications
- Replacement of degraded dockwater membrane during scheduled APC/DTS system service
- Restoration of spot-free water output from the shore connection while at marina berth
- Planned membrane replacement during dry-dock refit as part of full watermaker overhaul
- Supplementing potable water production from dockwater when seawater mode is not required
Installation & Compatibility Notes
- Compatible with: FCI Atlas+ APC/DTS (Framed, Modular), MaxQ+ APC/DTS (Framed, Modular), DTS+ Solo, DTS Mobile
- Fits the dockwater pressure vessel assembly — do not confuse with the seawater RO membrane (separate SKU)
- Lubricate O-rings before installation; inspect and replace O-rings (product port and end plug) at membrane change
- After installation, flush the new membrane before returning system to service
⚠️ Special Order Item — This product is not stocked in Sydney. Price and shipping from the USA are available upon request. Contact Y3 Marine for a quote.