Clark Pump Seal & O-Ring Kit (7%) — Ventura

$396.00

Genuine Spectra Clark Pump seal and O-ring service kit for the 7% (Ventura 150C) configuration. Contains all internal piston lip seals, O-rings, and housing seals required for a complete in-situ Clark Pump rebuild. Correct service action when test port flow confirms piston seal wear on a Ventura 150C.

Add to Quote
SKU: SW-KIT-HP-S&O-VT Categories: , Tags: ,

Description

Clark Pump Seal & O-Ring Kit — Ventura — genuine rebuild seals for the energy-recovery pump. From Y3 Marine.

About the Clark Pump Seal & O-Ring Kit — Ventura

The Clark Pump Seal & O-Ring Kit for the 7% Ventura contains every sealing component needed to restore internal integrity to a worn Clark Pump on the Ventura 150C. Because the Clark Pump operates continuously at feed-line pressure and uses a reciprocating piston design to transfer hydraulic energy, the piston lip seals and O-rings are the primary wear items — and the first components to inspect when recovery rate drops below 5.5% or total feed flow falls short of the 1.65 GPM (6.2 LPM) minimum benchmark.

Diagnosis before ordering — confirm the fault with the test port:

  • With the system running, press the Schrader valve on the Clark Pump test port (small port at the rear of the pump housing) — a short burst of air is normal (air compressed by the piston at the end of stroke)
  • Constant water flow from the test port = lip seal failure — this kit is the correct service action
  • No flow at all = the test port Schrader is blocked; clean and re-test
  • If total feed flow is 1.5 GPM or above but recovery rate is below 5.5%, and check valves have been inspected/replaced, suspect piston seals

Critical pre-service steps — strictly follow before opening the Clark Pump:

  • Open the Clark Pump pressure relief valve ½ turn counterclockwise to vent high pressure before any connections are loosened
  • Turn the yellow service valve to SERVICE position to isolate the high-pressure system from the feed pump
  • Flush the membrane with fresh water (30-minute flush cycle or manual freshwater flush via Spectra Connect) before commencing service

After rebuild: Run a flow test before restoring service. Ventura 150C benchmarks: 1.7 GPM (6.4 LPM) total flow, 6.5 GPH (24.6 LPH) product, 6.5% recovery. Minimum acceptable: 1.65 GPM total, 5.7 GPH product, 5.5% recovery. Confirm accumulator pre-charge is 65 PSI and pressure switch is set to 125 PSI cutout before returning to service.

Fits: Spectra Ventura 150C — 7% Clark Pump configuration only. For Ventura 200T (10%), see SW-KIT-HP-31-VT200. For Clark Pump check valve replacement, see SW-KIT-HP-CVK-VT.

Fitment & ordering

The Clark Pump Seal & O-Ring Kit — Ventura is a genuine Spectra part, supplied and supported by Y3 Marine for superyachts and commercial vessels. For the complete system see the Spectra Ventura watermaker, or browse our full Spectra Watermakers range. Contact Y3 Marine for fitment, cross-referencing and current stock. Reference: Spectra Watermakers.