Description
The CJC® HDU 27/54 Fine Filter is C.C.JENSEN’s double-capacity offline oil filter for medium-sized hydraulic and lube-oil systems aboard superyachts. It carries twice the filter media of the 27/27 in the same large 27-series housing, running as an offline ‘kidney loop’ to remove particles down to 0.8 µm, absorb water, and adsorb varnish and acidity — with longer service intervals on larger or harder-working oil volumes. Rated to 120 °C and Lloyd’s Register type approved, it suits hot lube oil and continuously loaded hydraulics.
1 Filter, 4 Solutions
Most in-line filters only catch particles. The HDU depth filter does four jobs at once: it removes particles (to 0.8 µm, 3 µm absolute), absorbs water into the cellulose fibres to drive the oil dry, neutralises acidity (oxidation by-products), and adsorbs varnish and sludge before they lacquer valves and bearings. The result is oil held at ISO cleanliness class 15/13/10 or better — far cleaner than the system’s own working filter can achieve.
How It Works
A CJC pump draws oil from the reservoir, through the filter inserts and back — a dedicated loop running in parallel with the system, not in series with it. Because it is offline it runs 24/7, including while the system is shut down, and inserts are changed without stopping the machinery it serves. Oil passes through the full depth of the cellulose media (where contamination is captured throughout the insert, not just on a surface), and clean, dry oil returns to the reservoir ready for use. A pressure gauge on the head shows insert loading, so changes are condition-based rather than guesswork.
HDU or PTU — Choosing by Water Ingress
CJC removes water two ways: by absorption (the HDU soaks it into the insert) or by separation (the PTU coalesces and drains it). The deciding question is whether the system has a continuous free-water source. With only condensation or occasional, dissolved water — a closed hydraulic system, a main-engine or genset lube system, a gearbox — the HDU 27/54 is the right answer, and it drives the oil bone-dry. Where the fluid carries continuous or bulk free water (a stern tube, a thruster, a leaking cooler, or any diesel fuel), the absorption media would saturate quickly: there, step up to the CJC PTU Filter Separator.
Where the HDU 27/54 Fits
The 27/54 carries twice the filter media of the 27/27 in the same large 27-series housing — a two-stack of inserts rather than one. That extra capacity suits medium-sized hydraulic and lube-oil systems where a single stack would fill too quickly: larger reservoirs, dirtier oil, or simply a longer interval between insert changes. It sits between the 27/27 and the larger 27/81 and 27/108 in CJC’s modular range, all sharing the same housing and inserts, so stepping up capacity never means changing the installation footprint. Y3 Marine sizes the unit to your reservoir volume, oil viscosity and operating temperature.
Built for Hot Oil
Like the rest of the 27-series (and unlike the 60 °C 15-series), the HDU 27/54 is designed for oil temperatures up to 120 °C — the working range of main-engine and generator lube-oil circuits and hard-working hydraulic systems. That higher temperature rating, combined with the double media volume, makes it a strong fit for the engine room’s larger, hotter oil duties.
Filter Inserts
The HDU 27/54 runs CJC’s 100% natural-cellulose depth inserts (a two-stack), all rated 3 µm absolute. The grade is matched to the fluid: a Type B insert for general hydraulic and lube oils (the best balance of fine filtration and dirt-holding), a Type A for low-viscosity or warm oils, and a Type F where diesel or thermal oils are involved. Inserts are stocked by Y3 Marine and changed in minutes, with no system shutdown.
Typical Superyacht Applications
- Main engine & generator lube oil on larger plant — extends oil life 2–10×, holds bearings and journals clean, and cuts the number of oil changes, with the capacity to go longer between insert changes.
- Medium-to-large hydraulic power packs — stabilisers, thrusters, cranes, davits and deck machinery on clean, closed circuits, where contamination is the number-one cause of servo-valve and pump failure.
- Reduction gears and gearboxes — keeping gear oil clean and dry between changes (use a PTU if the oil cooler is prone to leaking).
- Oil reservoir polishing — stripping condensation and fine particles from larger standing oil volumes.
Why It Pays on a Yacht
Cleaner oil extends component and oil life 2–10 times, which on a yacht means fewer oil changes and therefore less waste oil to store and land ashore — a real benefit given limited tankage and MARPOL Annex I disposal obligations. Because the unit is offline, servicing never forces a shutdown of the system it protects — you cannot stop a genset at anchor or a stabiliser underway to change a filter, but you can service an HDU at any time. The double capacity of the 27/54 simply means longer service intervals than the 27/27. For classed vessels, the HDU 27 is Lloyd’s Register type approved.
Flow rate & sizing
The HDU 27/54 runs at up to ~600 L/h depending on the pump fitted. This table breaks that range into representative flow options and the system oil volume each suits — sized to your oil volume, not the machine. Keep-clean figures assume ~3 turnovers a day; polishing a dirty or wet charge needs more turnovers, so the same flow suits a smaller volume (or a longer run). Exact pump is confirmed at quote.
| Pump flow rate | Oil processed / 24 h | Keeps a system clean (~3 turnovers/day) |
Polishes a charge (~7 turnovers/day) |
|---|---|---|---|
| 300 L/h | ~7,200 L | up to ~2,400 L | up to ~1,030 L |
| 450 L/h | ~10,800 L | up to ~3,600 L | up to ~1,540 L |
| 600 L/h | ~14,400 L | up to ~4,800 L | up to ~2,060 L |
How to size a CJC — the turnover rule
An offline filter cleans only a fraction of the contamination on each pass, so cleanliness builds up over repeated turnovers of the whole charge. Size the unit against your system oil volume, not the machine it sits on:
- Keep-clean (maintenance): size so the entire oil volume passes through ~3× every 24 hours. Run it continuously — even at rest.
- Clean-up / polishing: for a dirty or wet charge, run continuously until on-target — expect the full volume to pass ~7× to reach target cleanliness / dryness.
- Removing water: water leaves gradually, so keep polishing until below target (gear oils typically <200 ppm, ideally <100 ppm) and fix the ingress source.
Worked example: a 500 L gearbox at ~110 L/h turns the full charge over about every 4.5 hours — roughly 5× a day, comfortably in the maintenance band. Polishing that same charge from wet or dirty (~7 turnovers) takes about 32 hours of continuous running.
Specifications & Installation
- Type: CJC HDU 27/54 offline fine filter (hydraulic/lube oil purifier, absorption)
- Function: oil fine filtration — particles, water, acidity, varnish
- Filtration: 3 µm absolute; particles retained down to 0.8 µm; ISO 15/13/10 achievable
- Media: 100% natural-cellulose CJC depth-filter inserts, two-stack (double the 27/27 capacity)
- Design pressure: ≤ 0.6 MPa (6 bar)
- Design temperature: ≤ 120 °C
- Suitable fluids: hydraulic, lube and gear oils (clean/dry, low water ingress; suits hot lube-oil duty)
- Installation: offline kidney loop — draws from and returns to the reservoir, independent of the main circuit; low continuous flow runs 24/7
- Approval: Lloyd’s Register type approved (CJC Type HDU 27)
Supplied by Y3 Marine — contact us for selection, insert grade, pricing and lead time. We can size the unit to your reservoir and recommend the matching CJC inserts and spares.