Gen-Sep Gas/Water Separation Muffler

The Centek Gen-Sep is a fibreglass-reinforced-plastic (FRP) gas/water separation muffler for generator exhaust — it splits the cooling water from the exhaust gas and discharges them separately, for the quietest, driest transom discharge in the Centek range (25–30 dB). Used in conjunction with a Vernalift, it is especially effective where the genset is mounted midship or well forward. As a Centek Marine agent and service dealer, Y3 Marine sizes the Gen-Sep and the matching Vernalift to your genset’s exhaust and backpressure. Contact us for selection, pricing and lead time.

Add to Quote
SKU: N/A Category:

Description

The Centek Gen-Sep is a fibreglass-reinforced-plastic (FRP) gas/water separation muffler that splits the cooling water from the exhaust gas on a generator exhaust, discharging the two separately for the quietest, driest discharge in the Centek range. It is used in conjunction with a Vernalift and is especially effective where the genset is mounted amidships or well forward.

Centek Gen-Sep — why separate the gas and water

A standard wet exhaust discharges the gas and cooling water together — the pulsing, splashing “burble” you hear at the transom. On a generator running through the night at anchor, that noise carries. The Gen-Sep splits the two streams: the water drains away in a steady, quiet flow and the gas is discharged separately, eliminating the wet-exhaust burble and giving the quietest, driest discharge in the Centek range. It is especially effective where the genset is located amidships or well forward, with a long exhaust run to the hull side.

How the Separator Works

The wet exhaust (gas and cooling water) enters the separator, where the flow is slowed and redirected. The heavier water drops out and collects, draining overboard through a dedicated water outlet, while the lighter exhaust gas rises and leaves through a separate gas outlet. Two clean, separated streams replace one pulsing wet discharge — quieter at the transom and gentler on the hull.

Used With a Vernalift

The Gen-Sep is a separator, not a stand-alone muffler — it is used in conjunction with a Centek Vernalift. The Vernalift lifts and silences the exhaust and protects the genset from back-flooding; the Gen-Sep then separates the gas and water downstream for the quiet, dry discharge. Where space is tight, the Centek Combo-Sep combines a Vernalift and a separator in a single unit — ask Y3 Marine which suits your installation.

Why FRP — Not Stainless or Plastic

Like all Centek mufflers, the Gen-Sep is built in FRP: it survives a brief loss of cooling water that would soften or melt a plastic (polyethylene) unit or fail a welded stainless one; it will not corrode or suffer electrolysis (no welds, no galvanic couple); and it is light.

Backpressure

The Gen-Sep and its Vernalift add to the genset’s exhaust backpressure, which must stay within the engine maker’s maximum. Centek sizes the separator and muffler to the genset’s exhaust diameter and backpressure allowance; Y3 Marine makes the selection for you.

Selecting Your Gen-Sep

The right separator is set by the genset exhaust size, the matching Vernalift, and the backpressure allowance. As a Centek Marine agent and service dealer, Y3 Marine sizes the Gen-Sep and Vernalift together to your genset — send us the generator details, exhaust size and the routing to the hull side.

Key Features

  • FRP gas/water separation muffler for generator exhaust
  • Separates cooling water and exhaust gas into two outlets for a quiet, dry discharge
  • Best-in-range sound attenuation: 25–30 dB
  • Eliminates the wet-exhaust “burble” at the transom — quiet-ship at anchor
  • Especially effective for midship or forward-mounted gensets
  • Used in conjunction with a Centek Vernalift (or see the integrated Combo-Sep)
  • FRP — no corrosion, no electrolysis, no weld failure; survives brief cooling-water loss
  • Inlet/outlet 1.5″ to 5″; custom sizes to order; above-waterline

Typical Superyacht Applications

  • Generator exhaust where the genset is amidships or well forward
  • Quiet-ship operation — night generator running at anchor
  • Where a dry, separated transom discharge is preferred over a wet outlet

Installation & Compatibility

  • Above-waterline installation, downstream of a Centek Vernalift
  • Route the separate gas and water outlets to the hull side
  • Size to the genset exhaust diameter and backpressure allowance
  • For a single combined unit, see the Centek Combo-Sep (Vernalift + separator)

Additional information

Brand

Centek Marine

Product Type

Generator gas/water separation muffler

Construction

Fibreglass-reinforced plastic (FRP)

Sound Attenuation

25–30 dB

Function

Separates exhaust gas and cooling water into two outlets

Use With

Centek Vernalift muffler (or integrated Combo-Sep)

Inlet/Outlet Sizes

1.5" to 5" (custom sizes to order)

Waterline

Above-waterline

Selection Basis

Genset exhaust diameter, matching Vernalift, max backpressure

Dimensions (H × W × D)

mm, per size: 1.5"/2" — 397 × 314 × 137; 2.5" — 533 × 457 × 194; 3" — 533 × 457 × 186; 3.5"/4" — 686 × 597 × 233; 5" — 686 × 597 × 233. Approx.; exact per part on request.

Finish & Colour

Standard white gelcoat; custom colours and finishes available to order

Availability

Supplied to order — by request only (not held in stock)