Description
The Calpeda NR4 circulation pump is a low-speed, flanged in-line circulator for superyacht HVAC chilled-water, glycol-heating and jacket-water circuits — quiet 4-pole running, rated to 90°C and 10 bar.
The Calpeda NR4 is a flanged in-line centrifugal circulation pump running at ≈1,450 rpm — half the speed of standard 2-pole pumps — making it the right choice for noise-sensitive superyacht environments. Low rotational speed means reduced vibration, quieter operation, and extended bearing life compared to 2-pole equivalents. With suction and delivery connections on the same centreline and the same diameter, the NR4 drops directly into existing pipework without modification. The range covers DN32 to DN80, with powers from 0.25 kW to 5.5 kW, handling flow rates to 96 m³/h and heads to 21 m — well suited to HVAC chilled water distribution, glycol heating loops, hot water circuits, and engine jacket water closed-side circulation aboard superyachts and commercial vessels.
Calpeda NR4 Circulation Pump — Key Specifications
| Model | Connections (DN) | Power Range | Max Head | Max Flow | Flange Standard |
|---|---|---|---|---|---|
| NR4 32 | DN32 (PN10-16) | 0.37 – 0.75 kW | 14.6 m | 9.6 m³/h | EN 1092-2 |
| NR4 40 | DN40 (PN10-16) | 0.37 – 0.75 kW | 14.7 m | 15 m³/h | EN 1092-2 |
| NR4 50 | DN50 (PN10-16) | 0.25 – 2.2 kW | 21 m | 30 m³/h | EN 1092-2 |
| NR4 65 (large-vessel / high-capacity) | DN65 (PN10-16) | 0.37 – 4 kW | 21.4 m | 48 m³/h | EN 1092-2 |
| NR4 80 (large-vessel / high-capacity) | DN80 (PN10-16) | 1.1 – 5.5 kW | 20.3 m | 96 m³/h | EN 1092-2 |
NR4 32–50 (chiller plant up to ~200 kW) cover the great majority of yacht HVAC and heating loops. NR4 65 and NR4 80 are large-vessel / high-capacity plant sizes — specify these only for very large chiller plant or commercial vessels.
Construction & Materials
- Pump casing & lantern bracket: Cast iron GJL 200 (EN 1561) — appropriate for inhibited glycol, hot water, and freshwater closed-loop service
- Impeller: Cast iron GJL 200 (EN 1561); brass impeller available on request
- In-line design: Suction and delivery on the same axis, same port diameter — drops into existing pipework without changes to pipe alignment
- Flanged connections: EN 1092-2, PN 10-16 — compatible with standard marine and industrial flanged pipework
- 4-pole induction motor, 50 Hz: ≈1,450 rpm — half the speed of standard circulation pumps; lower noise, lower vibration, extended bearing and seal life
- Motor supply: Three-phase 230/400V ±10% (up to 3 kW); 400/690V ±10% (from 4 kW)
- Motor insulation: Class F
- Motor protection: IP54
- Efficiency class: IE3 (three-phase); IE2 (single-phase up to 1.1 kW)
- Frequency converter compatible: from 0.37 kW — enables variable speed control for HVAC and heating system optimisation
- Liquid temperature: −10°C to +90°C
- Max working pressure: 10 bar
- Duty: Continuous S1 (three-phase)
Applications
- HVAC chilled water distribution: Primary and secondary circulation in chilled water air conditioning systems. The 4-pole low-speed motor is quieter than 2-pole equivalents — important for pumps located in or near accommodation spaces.
- Glycol and hot water heating loops: Circulates inhibited glycol or hot water through underfloor heating, radiator circuits, and thermal buffer systems. Rated to 90°C continuous — suitable for most hydronic heating applications.
- Engine jacket water — closed freshwater side: Auxiliary circulation on the freshwater side of engine cooling circuits, including pre-heating loops and thermal management systems. Not for seawater or open cooling circuits.
- Variable speed HVAC systems: Frequency converter compatibility from 0.37 kW allows the NR4 to be controlled by a BMS or VFD for load-matched operation — reducing energy consumption and extending pump life in variable-demand systems.
Why Cast Iron for Closed-Loop Service
Unlike the open marine circuits handled by Y3 Marine’s bronze pump range, closed hydronic loops — chilled water, glycol, and hot water heating — use inhibited fluid that is non-corrosive to cast iron. Bronze adds unnecessary cost and weight in this application. The NR4 in cast iron GJL 200 is the correct specification for closed-loop service on superyachts and commercial vessels, and it is available through Calpeda Australia. Contact Y3 Marine to confirm availability and lead time.
Protection & Standards
- IP54 standard; IP55 available on request
- Constructed in accordance with EN 60034-1, EN 60034-30-1, EN 60335-1, EN 60335-2-41
- Complies with European Regulation No. 547/2012 (hydraulic efficiency)
- Tolerances per UNI EN ISO 9906:2012
Important Notes
- The NR4 is designed for clean liquids without abrasives (solids content up to 0.2%). Not suitable for seawater, black water, grey water, or bilge service.
- Maximum suction lift: 7 m.
- For installations requiring duty/standby redundancy in a single unit, ask Y3 Marine about the Calpeda NRD4 twin-head variant (DN50 and DN65).
- The 2-pole NR series (≈2,900 rpm, up to 22 kW, DN32–DN80) is available on enquiry for applications requiring higher head or flow at a given pipe size.
- Single-phase supply (NR4M) is available at 0.25 kW only (DN50 and DN65). Contact Y3 Marine for single-phase requirements.
- Other voltages, 60 Hz, and stainless steel impellers are available on request.
Installation Requirements
- Flanged connections EN 1092-2, PN 10-16 — counter-flanges available on request
- In-line installation: pump mounts directly in the pipeline on the same centreline; no base frame required for smaller sizes
- Frequency converter versions available on request (I-MAT integrated VFD option)
- Three-phase wiring: 230/400V up to 3 kW; 400/690V from 4 kW
Engineering & Selection Notes
- NPSH / cavitation: not self-priming — keep the NPSH available at the inlet at least 0.5 m above the pump’s NPSH required (Calpeda curve). NPSHa = atmospheric + static suction head − vapour pressure − suction losses (m of liquid); hot-liquid duty raises vapour pressure and needs extra margin. Y3 Marine confirms NPSHr for your model.
- Reading the table: max flow and max head are curve endpoints — max flow occurs near zero head and max head near zero flow. The real duty sits on the curve between them, ideally near the best-efficiency point; Y3 Marine selects to your duty point.
- Engine-room ambient: motor ratings assume ≤40 °C ambient; engine rooms often run hotter, so above 40 °C de-rate the motor or step up a frame size to avoid thermal overload.
- Generator starting: direct-on-line start draws ~6–8× full-load current — on larger three-phase motors use star-delta, soft-start or a VSD and check inrush against available generator capacity.