Description
The Calpeda NGX jet pump is a self-priming stainless-steel pump for marine freshwater supply — it clears air and primes from a dry line, lifting water up to 9 m, ideal for tank-fed systems mounted above the waterline.
Calpeda NGX Jet Pump — Key Specifications
| Model | Max Head | Max Flow | Power | Suction | Delivery |
|---|---|---|---|---|---|
| NGX 2/80 | 46.8 m | 3.6 m³/h | 0.55 kW | G1 (1″ BSPP) | G1 (1″ BSPP) |
| NGX 3/100 | 50 m | 3.6 m³/h | 0.65 kW | G1 (1″ BSPP) | G1 (1″ BSPP) |
| NGX 4/110 | 41.6 m | 4.5 m³/h | 0.75 kW | G1 (1″ BSPP) | G1 (1″ BSPP) |
| NGX 4/16 | 57.5 m | 5.5 m³/h | 1.1 kW | G1¼ (1¼″ BSPP) | G1 (1″ BSPP) |
| NGX 4/18 | 48 m | 6.5 m³/h | 1.1 kW | G1¼ (1¼″ BSPP) | G1 (1″ BSPP) |
| NGX 4/22 | 35.5 m | 8.4 m³/h | 1.1 kW | G1¼ (1¼″ BSPP) | G1 (1″ BSPP) |
| NGX 6/18 | 58 m | 6 m³/h | 1.5 kW | G1¼ (1¼″ BSPP) | G1 (1″ BSPP) |
| NGX 6/22 | 46.5 m | 8.4 m³/h | 1.5 kW | G1¼ (1¼″ BSPP) | G1 (1″ BSPP) |
All figures at rated speed (~2800 rpm), flooded suction, 20°C water. Head and flow reduce with increasing suction lift.
Construction & Materials
The NGX distinguishes itself from the cast iron NG series with a pump casing and casing cover in AISI 304 chrome-nickel stainless steel — significantly better corrosion resistance in the humid, salt-air environment of a vessel’s machinery space. The impeller is brass (CW617N) on NGX 4/16 through 6/22; Noryl PPO-GF20 on the smaller NGX 2/80, 3/100 and 4/110. The diffuser and built-in ejector are Noryl PPO-GF20. Shaft is stainless steel. Mechanical seal is carbon/ceramic/NBR. The pump is close-coupled to an IEC standard motor, keeping the overall footprint compact and motor replacement simple.
Applications
The NGX’s ejector design makes it particularly well suited to situations where the water supply may contain entrained air — common in marine freshwater systems where tanks can run low or where long suction lines trap air pockets. Typical uses aboard include:
- Freshwater pressure boost and distribution
- Tank-to-tap supply where the pump is installed above the tank
- Watermaker pre-feed from low or variable-level tanks
- Deck wash supply
- Transfer from sumps or low-level holding tanks
Note: Maximum liquid temperature is 35°C. The NGX is suited to clean or slightly dirty fresh water only — it is not designed for bilge duty or high-temperature service.
NGX vs BNG — Which to Choose?
The NGX and BNG are mechanically identical self-priming jet pumps — same ejector design, same performance envelope, same motor options. The difference is entirely in the casing material, which affects cost, weight, temperature rating, pressure rating, and the size of pump available.
| NGX (Stainless Steel) | BNG (Bronze) | |
|---|---|---|
| Casing | AISI 304 stainless steel | Bronze CC480K |
| Max liquid temp | 35°C | 40°C |
| Max pressure | 8 bar | 10 bar |
| Largest model | NGX 6/22 (1.5 kW, 58 m max head) | BNG 7/22 (2.2 kW, 95 m max head) |
| Weight | 8–18 kg (lighter) | 21–38 kg (heavier) |
| Cost | Lower | Higher |
| Best for | Weight-sensitive installs, cold freshwater, modest duties | Higher pressure/temp, larger duties, long service life |
Choose NGX if: weight is a priority, your duty point sits within the NGX range, and liquid temperature stays below 35°C.
Choose BNG if: you need the larger BNG 7 series, require 10 bar system pressure, expect liquid temperatures above 35°C, or want the proven longevity of bronze in a salt-air engine room.
Protection & Standards
Motor enclosure IP54 (splash-proof). Insulation class F. Three-phase motors IE3 efficiency class (IE2 for motors up to 0.65 kW); single-phase motors IE2 up to 1.1 kW. Built to EN 60034-1, EN 60034-30-1, EN 60335-1, EN 60335-2-41. CE marked. Maximum starts per hour: 40 at regular intervals.
Duty Cycle
Three-phase models (NGX) are rated S1 — continuous duty: the pump can run indefinitely at rated load without a rest period. Single-phase models (NGXM) up to 1.5 kW are rated S3 60% — intermittent duty: 6 minutes running followed by 4 minutes rest per 10-minute cycle. For high-cycle or continuously running applications, specify the three-phase variant.
Important Notes
- The NGX is the stainless steel casing variant. Cast iron (NG) and bronze (B-NG) versions available on request.
- Single-phase (NGXM) available across the full model range.
- Three-phase motors: 230/400V ±10%. Single-phase motors: 230V ±10%.
- Suction lift up to 9 m — pump must be initially primed (filled with water) before first start.
- A non-return valve on the suction line is strongly recommended to retain prime after shutdown.
- Liquid temperature limited to 35°C.
Installation Requirements
The NGX is designed for horizontal installation with the motor shaft horizontal and the support feet facing down. Install as close as possible to the water source to minimise suction losses. The suction pipe must be airtight — any air ingress will degrade self-priming performance. A non-return (foot) valve at the bottom of the suction line retains the water column after shutdown, reducing re-priming time on restart. Before first start, fill the pump body completely with clean water through the priming port. For three-phase connection, verify rotation direction matches the arrow on the pump housing. Provide isolation valves on suction and delivery to facilitate servicing. Allow adequate clearance around the motor for ventilation.
Engineering & Selection Notes
- Reading the table: max flow and max head are curve endpoints — max flow occurs near zero head and max head near zero flow. The real duty sits on the curve between them, ideally near the best-efficiency point; Y3 Marine selects to your duty point.
- Engine-room ambient: motor ratings assume ≤40 °C ambient; engine rooms often run hotter, so above 40 °C de-rate the motor or step up a frame size to avoid thermal overload.