Description
The Calpeda NCE circulation pump is a high-efficiency, variable-speed circulator for superyacht domestic hot water, heating and glycol loops — a permanent-magnet inverter drive that draws only the power the system demands, at ≤43 dB(A).
The Calpeda NCE series are high-efficiency variable speed circulating pumps driven by permanent magnet synchronous motors with onboard inverters — consuming only as much power as the system demands. All models operate at ≤43 dB(A), making them suited to the noise-sensitive environment of a superyacht or motor vessel. The range covers domestic hot water recirculation (DHW), heating and glycol loops, and larger twin-head HVAC installations with full BMS integration. All models run on single-phase 230V, 50/60 Hz.
Calpeda NCE Circulation Pump — Model Comparison
| Model | Application | Casing | Connections | Max Flow | Max Head | Power Range | Max Temp | Max Pressure |
|---|---|---|---|---|---|---|---|---|
| NCE ES | Sanitary DHW recirculation | Bronze | G1 – G1½ threaded | 3.3 m³/h | 3.8 m | 4.5 – 44 W | 95°C | 10 bar |
| NCE PS2 | Sanitary DHW recirculation | Bronze | G1 – G1½ threaded | 2.6 m³/h | 6.0 m | 10 – 45 W | 95°C | 10 bar |
| NCE EI | Heating & glycol loops | Cast iron | G1 – G2 threaded | 4.2 m³/h | 6.8 m | 3 – 56 W | 95°C | 6 bar |
| NCE HQ 2 | Twin-head HVAC, BMS systems | Cast iron | G1½ – G2 + flanges | 48 m³/h | 17 m | 15 W – 1.26 kW | 110°C | 10 bar |
Common Features — All NCE Models
- Motor technology: Permanent magnet synchronous motor (PM) controlled by onboard inverter — variable speed, load-matched energy consumption
- Supply: Single-phase 230V ±10%, 50/60 Hz
- Motor protection: IP44; integrated overload and thermal protection
- Noise: ≤43 dB(A) — suitable for accommodation and machinery spaces near crew areas
- EEI benchmark: EEI ≤ 0.20 — highest circulator efficiency class
- Certifications: CE, EN 60335-1, EN 60335-2-51, EMC per EN 55014-1/2, EN 61000-3-2/3
NCE ES — Sanitary Hot Water Recirculation (Bronze)
The NCE ES is purpose-built for domestic hot water recirculation in potable water systems. Bronze pump casing makes it suitable for contact with drinking water. Ideal for DHW loops on smaller vessels where the pump is located above the calorifier or in a plant room adjacent to accommodation. Composite impeller, ceramic shaft and EPDM gaskets — no ferrous components in the flow path.
- Bronze pump casing — potable water safe
- Composite impeller, ceramic shaft, EPDM gaskets
- Connections: G1, G1¼, G1½ (BSP threaded, ISO 228)
- Liquid temperature: +2°C to +95°C
- Max pressure: 10 bar
- Power: 4.5–44 W
- Three manual speed curves selectable via dial
NCE PS2 — Sanitary Hot Water Recirculation, Higher Head (Bronze)
The NCE PS2 is the higher-head bronze DHW circulator — offering up to 6m compared to the NCE ES’s 3.8m — making it the better choice for longer DHW recirculation loops or where the calorifier is located further from the distribution point. Features a digital display and advanced control modes. Also bronze casing for potable water service.
- Bronze pump casing — potable water safe
- Higher head capability: up to 6m (vs NCE ES at 3.8m)
- Connections: G1 – G1½ (BSP threaded)
- Liquid temperature: +2°C to +95°C
- Max pressure: 10 bar
- Power: 10–45 W
- Digital display with multiple operating modes
NCE EI — Heating and Glycol Loop Circulation
The NCE EI is Calpeda’s standard high-efficiency heating circulator for closed-loop service — underfloor heating, radiator circuits, and glycol heating loops. Not for potable water. Accepts up to 40% glycol concentration, making it suitable for refrigeration pre-heating loops, frost protection circuits, and thermal buffer systems aboard vessels operating in cold climates.
- For non-potable heating water and glycol solutions (up to 40%)
- Connections: G1, G1½, G2 (BSP threaded)
- Liquid temperature: +2°C to +95°C
- Max pressure: 6 bar
- Power: 3–56 W
- Three automatic operating modes: constant pressure, proportional pressure, constant curve
- Insulation class H
NCE HQ 2 — Twin-Head Heating Circulator with BMS Integration
The NCE HQ 2 is the largest NCE variant and the one to specify when duty/standby redundancy and BMS integration are required. Twin-head design provides built-in redundancy — if one head fails, the other takes over automatically. Full digital I/O including Modbus RS485 and TCP/IP makes it directly connectable to vessel management and building automation systems. Suitable for primary HVAC heating loops, large DHW systems, and multi-zone underfloor heating on larger yachts.
- Twin-head configuration: built-in duty/standby redundancy
- Connections: G1½, G2 threaded; flanged connections available
- Liquid temperature: −10°C to +110°C — widest temperature range in the NCE range
- Max pressure: 10 bar
- Power: 15W – 1.26 kW — covers large primary loops
- Digital I/O: Start/stop input, relay output, 0-10V input, 4-20 mA input
- Modbus RS485 and TCP/IP — direct BMS integration
- Dry running detection and automatic venting function
- Max glycol: 20%
- Sound pressure ≤40 dB(A)
Important Notes
- NCE ES and NCE PS2 are the only models with bronze casings — use these where the pump contacts potable or sanitary water.
- NCE EI and NCE HQ 2 have cast iron casings — for closed heating and glycol loops only, not potable water.
- All models are single-phase 230V only — not available in three-phase.
- The NCE HQ 2 is significantly larger and heavier than the other NCE models. Contact Y3 Marine for dimensional drawings before specifying.
- All NCE models are sourced to order via Calpeda Australia; contact Y3 Marine to confirm availability and lead time.