Calpeda MXV-B Vertical Multi-Stage Close-Coupled Pump

The Calpeda MXV-B is a fixed-speed vertical multi-stage close-coupled pump in stainless steel — a compact, self-contained unit where the motor is integral to the pump body, requiring no separate coupling or baseplate. Suited to standalone freshwater pressure boosting, wash-down service, and tank transfer on yachts and vessels where a simple, space-efficient fixed-speed solution is preferred over a full booster set.

Add to Quote
SKU: N/A Category:

Description

The Calpeda MXV-B multi-stage pump is a vertical, close-coupled (monobloc) stainless-steel pump for marine freshwater supply and pressure boosting — a compact, self-contained alternative to a full booster set.

Calpeda MXV-B Multi-Stage Pump — Calpeda MXV-B — Vertical Multi-Stage Close-Coupled Pump

Fixed Speed. Compact. Self-Contained.

The MXV-B is Calpeda’s close-coupled (monobloc) vertical multi-stage pump — the motor is integral to the pump body, with no shaft coupling, alignment procedure, or separate baseplate required. It is a fixed-speed pump: straightforward to install, simple to maintain, and well suited to applications where constant-pressure variable-speed control is not required.

How It Differs from the BS.MXV Booster Set

The BS.MXV is a factory-assembled multi-pump pressure boosting station with manifold pipework, isolation valves, a microprocessor control panel, and optional VFD for variable-speed constant-pressure operation across 1 to 3 pumps. The MXV-B is none of those things — it is a single fixed-speed pump unit. Choose the MXV-B when you need a compact standalone pump for a defined duty point; choose the BS.MXV when you need a complete pressurisation system with redundancy and automatic control.

Marine Applications

  • Standalone freshwater pressure boosting on smaller yachts and vessels
  • Secondary or dedicated service water circuits
  • High-pressure wash-down systems
  • Tank-to-tank transfer
  • Fire-fighting jockey pump duty
  • Custom-built booster assemblies where the installer supplies their own panel and pipework

Performance by Model

Model Max Flow Max Head Motor Power Range Connection
MXV-B 25 ~3 m³/h 228 m 0.75–3 kW 1″ BSPP
MXV-B 32 ~8 m³/h 205 m 1.1–4 kW 1¼” BSPP
MXV-B 40 ~14 m³/h 226 m 1.5–7.5 kW 1½” BSPP
MXV-B 50 ~20 m³/h 267 m 1.1–18.5 kW 2″ BSPP

Max head figures are the tallest stage-stack builds (up to ~27 bar), suited to firefighting, RO feed and commercial duty. For yacht domestic boosting, a low-stage MXV-B delivering ~4–6 bar at the required flow is the correct selection — Y3 Marine sizes the stage count to your pressure.

Materials

  • Standard (MXV-B): Wetted internals in AISI 304 stainless steel.
  • 316L option (MXVL-B): Full AISI 316L stainless steel for desalinated water, aggressive treated water, or where 316L certification is required.

Installation Note

The MXV-B is not self-priming and requires a flooded suction — the water source (tank or manifold) must be at or above the pump inlet. If the pump will be installed above the tank or water level, consider the Calpeda A Series self-priming pump instead.

The MXV-B is a configured-to-order pump — specify required flow rate (m³/h), total head (m), voltage, and liquid temperature when enquiring. Contact Y3 Marine for selection and quotation.

Duty Cycle

Three-phase MXV-B motors are rated for continuous duty (S1) — meaning the motor can run at full load indefinitely without overheating, suitable for constant freshwater supply. Single-phase motors up to 1.5 kW are rated S3 60% (intermittent duty) — the motor runs for 6 minutes in every 10-minute cycle and must rest for the remaining 4 minutes. This is fine for pressure boosting where the pump cycles on and off with demand, but not suitable for extended continuous operation such as tank transfers or prolonged wash-down. For continuous freshwater supply duty, specify three-phase.

Engineering & Selection Notes

  • NPSH / cavitation: not self-priming — keep the NPSH available at the inlet at least 0.5 m above the pump’s NPSH required (Calpeda curve). NPSHa = atmospheric + static suction head − vapour pressure − suction losses (m of liquid); hot-liquid duty raises vapour pressure and needs extra margin. Y3 Marine confirms NPSHr for your model.
  • Reading the table: max flow and max head are curve endpoints — max flow occurs near zero head and max head near zero flow. The real duty sits on the curve between them, ideally near the best-efficiency point; Y3 Marine selects to your duty point.
  • Engine-room ambient: motor ratings assume ≤40 °C ambient; engine rooms often run hotter, so above 40 °C de-rate the motor or step up a frame size to avoid thermal overload.
  • Generator starting: direct-on-line start draws ~6–8× full-load current — on larger three-phase motors use star-delta, soft-start or a VSD and check inrush against available generator capacity.
  • Minimum flow: multistage pumps overheat if run against a closed valve (dead-headed) — fit a minimum-flow bypass or thermal protection on circuits that may run with all outlets shut.

Additional information

Model

MXV-B 25, MXV-B 32, MXV-B 40, MXV-B 50

Motor

Three-phase, Single-phase

Pump Type

Vertical multi-stage close-coupled (monobloc)

Speed

Fixed speed, 2,900 rpm, 2-pole, 50 Hz

Voltage

Three-phase 230/400 V up to 3 kW; 400/690 V from 4 kW | Single-phase 230 V up to 2.2 kW (MXV-BM)

Max Working Pressure

16 bar

Liquid Temperature

−15°C to +90°C

Motor Protection

IP54

Insulation Class

Class F, IE3 (three-phase), IE2 (single-phase)

Wetted Materials

AISI 304 stainless steel standard (MXV-B); AISI 316L option (MXVL-B)

Connections

MXV-B 25: 1" BSPP, MXV-B 32: 1¼" BSPP, MXV-B 40: 1½" BSPP, MXV-B 50: 2" BSPP

Brand

Calpeda

Duty Cycle

Three-phase: Continuous duty (S1), Single-phase up to 1.5 kW: Intermittent duty (S3 60% — 6 min run / 4 min rest per 10-min cycle)

Brand

Calpeda

We respond to the different requirements for optimal integrated water cycle management