Description
The Calpeda MXV-B multi-stage pump is a vertical, close-coupled (monobloc) stainless-steel pump for marine freshwater supply and pressure boosting — a compact, self-contained alternative to a full booster set.
Calpeda MXV-B Multi-Stage Pump — Calpeda MXV-B — Vertical Multi-Stage Close-Coupled Pump
Fixed Speed. Compact. Self-Contained.
The MXV-B is Calpeda’s close-coupled (monobloc) vertical multi-stage pump — the motor is integral to the pump body, with no shaft coupling, alignment procedure, or separate baseplate required. It is a fixed-speed pump: straightforward to install, simple to maintain, and well suited to applications where constant-pressure variable-speed control is not required.
How It Differs from the BS.MXV Booster Set
The BS.MXV is a factory-assembled multi-pump pressure boosting station with manifold pipework, isolation valves, a microprocessor control panel, and optional VFD for variable-speed constant-pressure operation across 1 to 3 pumps. The MXV-B is none of those things — it is a single fixed-speed pump unit. Choose the MXV-B when you need a compact standalone pump for a defined duty point; choose the BS.MXV when you need a complete pressurisation system with redundancy and automatic control.
Marine Applications
- Standalone freshwater pressure boosting on smaller yachts and vessels
- Secondary or dedicated service water circuits
- High-pressure wash-down systems
- Tank-to-tank transfer
- Fire-fighting jockey pump duty
- Custom-built booster assemblies where the installer supplies their own panel and pipework
Performance by Model
| Model | Max Flow | Max Head | Motor Power Range | Connection |
|---|---|---|---|---|
| MXV-B 25 | ~3 m³/h | 228 m | 0.75–3 kW | 1″ BSPP |
| MXV-B 32 | ~8 m³/h | 205 m | 1.1–4 kW | 1¼” BSPP |
| MXV-B 40 | ~14 m³/h | 226 m | 1.5–7.5 kW | 1½” BSPP |
| MXV-B 50 | ~20 m³/h | 267 m | 1.1–18.5 kW | 2″ BSPP |
Max head figures are the tallest stage-stack builds (up to ~27 bar), suited to firefighting, RO feed and commercial duty. For yacht domestic boosting, a low-stage MXV-B delivering ~4–6 bar at the required flow is the correct selection — Y3 Marine sizes the stage count to your pressure.
Materials
- Standard (MXV-B): Wetted internals in AISI 304 stainless steel.
- 316L option (MXVL-B): Full AISI 316L stainless steel for desalinated water, aggressive treated water, or where 316L certification is required.
Installation Note
The MXV-B is not self-priming and requires a flooded suction — the water source (tank or manifold) must be at or above the pump inlet. If the pump will be installed above the tank or water level, consider the Calpeda A Series self-priming pump instead.
The MXV-B is a configured-to-order pump — specify required flow rate (m³/h), total head (m), voltage, and liquid temperature when enquiring. Contact Y3 Marine for selection and quotation.
Duty Cycle
Three-phase MXV-B motors are rated for continuous duty (S1) — meaning the motor can run at full load indefinitely without overheating, suitable for constant freshwater supply. Single-phase motors up to 1.5 kW are rated S3 60% (intermittent duty) — the motor runs for 6 minutes in every 10-minute cycle and must rest for the remaining 4 minutes. This is fine for pressure boosting where the pump cycles on and off with demand, but not suitable for extended continuous operation such as tank transfers or prolonged wash-down. For continuous freshwater supply duty, specify three-phase.
Engineering & Selection Notes
- NPSH / cavitation: not self-priming — keep the NPSH available at the inlet at least 0.5 m above the pump’s NPSH required (Calpeda curve). NPSHa = atmospheric + static suction head − vapour pressure − suction losses (m of liquid); hot-liquid duty raises vapour pressure and needs extra margin. Y3 Marine confirms NPSHr for your model.
- Reading the table: max flow and max head are curve endpoints — max flow occurs near zero head and max head near zero flow. The real duty sits on the curve between them, ideally near the best-efficiency point; Y3 Marine selects to your duty point.
- Engine-room ambient: motor ratings assume ≤40 °C ambient; engine rooms often run hotter, so above 40 °C de-rate the motor or step up a frame size to avoid thermal overload.
- Generator starting: direct-on-line start draws ~6–8× full-load current — on larger three-phase motors use star-delta, soft-start or a VSD and check inrush against available generator capacity.
- Minimum flow: multistage pumps overheat if run against a closed valve (dead-headed) — fit a minimum-flow bypass or thermal protection on circuits that may run with all outlets shut.