Description
The Calpeda MXH multi-stage pump is a horizontal, close-coupled stainless-steel pump for marine freshwater supply and pressure boosting — compact, quiet and rated for S1 continuous duty aboard yachts and commercial vessels.
Calpeda MXH Multi-Stage Pump — Key Specifications
| Model | Max Flow | Max Head | Power Range | Suction | Delivery |
|---|---|---|---|---|---|
| MXH 2 | 4.8 m³/h | 103 m | 0.25–1.5 kW | G1¼ (1¼″ BSPP) | G1 (1″ BSPP) |
| MXH 4 | 8 m³/h | 103.5 m | 0.37–2.2 kW | G1¼ (1¼″ BSPP) | G1 (1″ BSPP) |
| MXH 8 | 13 m³/h | 95.5 m | 0.75–3 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| MXH 16 | 25 m³/h | 71 m | 1.5–5.5 kW | G2 (2″ BSPP) | G1½ (1½″ BSPP) |
| MXH 20 | 24 m³/h | 89 m | 1.1–5.5 kW | G2 (2″ BSPP) | G1½ (1½″ BSPP) |
| MXH 32 (on request — high-flow/commercial) | 50 m³/h | 74.5 m | 2.2–7.5 kW | G2½ (2½″ BSPP) | G2 (2″ BSPP) |
MXH 48 and above available on request. All figures at rated speed; performance varies by stage count.
For yacht freshwater supply, MXH 2–8 (≈5–13 m³/h) cover the domestic range. MXH 16 and 20 are high-flow sizes for ballast transfer and deck-wash ring mains. MXH 32 (50 m³/h) is a commercial-scale build, supplied on request.
Construction & Materials
The MXH uses a horizontal multi-stage design with stainless steel hydraulics throughout. All wetted parts — impellers, diffusers, intermediate rings, suction and delivery covers — are AISI 304 stainless steel as standard. The shaft is AISI 316L stainless steel. For aggressive water conditions or saltwater-adjacent applications, the MXHL variant (available in MXH 2, 4 and 8) upgrades all hydraulic components to AISI 316L. The mechanical seal is carbon/ceramic/NBR, and the motor is a close-coupled IEC standard frame — making motor replacement straightforward without disturbing the pump hydraulics.
Connections are BSP parallel (ISO 228) thread as standard; MXH 20 and 32 are also available with flanged ports (-F suffix) or Victaulic couplings (-V suffix, MXH 32 only).
Applications
The MXH is a practical pump for vessels where a horizontal orientation suits the engine room layout better than a vertical multi-stage (such as the MXV-B). Typical uses include:
- Freshwater pressure and distribution
- Ballast transfer
- Deck wash
Unlike the MÈTA self-priming pump, the MXH requires a flooded suction — it must be installed below the water source or fed from a pressurised header tank. Where a self-priming capability is needed, refer to the Calpeda MÈTA BS.
Protection & Standards
Motor enclosure is IP54 (splash-proof) — suitable for engine room and machinery space installation where water spray is possible but total submersion does not occur. Motors are IE3 efficiency class (three-phase) or IE1 (single-phase). Insulation class F. Built to IEC 60034 and CE marked. Variable speed (I-MAT inverter) versions are available as MXH EI — contact us for details.
Duty Cycle
The MXH motor is rated S1 — continuous duty. This means the pump can run indefinitely at rated load without a mandatory rest period. S1 duty makes the MXH well suited to high-cycle domestic water systems and watermaker feed applications where the pump may run for extended periods.
Important Notes
- Single-phase (230V, 50Hz) motors available for MXH 2, 4, and 8. MXH 16 single-phase is limited to small-stage variants (MXHM 1602/1603, max ~1.8 kW). MXH 20 and 32 are three-phase only.
- Three-phase motors: 230/400V up to 3 kW; 400/690V from 3.7 kW upward.
- AISI 316L hydraulic option (MXHL series) available for MXH 2, 4, and 8 — specify at order.
- Flanged port option (-F) available for MXH 20 and 32; Victaulic coupling option (-V) for MXH 32.
- Variable speed (I-MAT integrated inverter) versions available as MXH EI — enquire for pricing.
- MXH 32, MXH 48 and larger sizes are supplied on request.
Installation Requirements
Flooded suction required. The MXH is not self-priming and must be installed so the suction port is fed by gravity or positive pressure from the water source at all times. Install the pump below the supply tank or header tank, or ensure the supply line is always full and pressurised before start-up. A foot valve or non-return valve on the suction line is recommended to prevent drainage during shutdown. Provide isolation valves on both suction and delivery to facilitate servicing. The motor fan requires adequate ventilation — minimum 50 mm clearance around the motor casing. Flexible connections on suction and delivery are recommended to isolate vibration from pipework.
Engineering & Selection Notes
- NPSH / cavitation: not self-priming — keep the NPSH available at the inlet at least 0.5 m above the pump’s NPSH required (Calpeda curve). NPSHa = atmospheric + static suction head − vapour pressure − suction losses (m of liquid); hot-liquid duty raises vapour pressure and needs extra margin. Y3 Marine confirms NPSHr for your model.
- Reading the table: max flow and max head are curve endpoints — max flow occurs near zero head and max head near zero flow. The real duty sits on the curve between them, ideally near the best-efficiency point; Y3 Marine selects to your duty point.
- Engine-room ambient: motor ratings assume ≤40 °C ambient; engine rooms often run hotter, so above 40 °C de-rate the motor or step up a frame size to avoid thermal overload.
- Generator starting: direct-on-line start draws ~6–8× full-load current — on larger three-phase motors use star-delta, soft-start or a VSD and check inrush against available generator capacity.
- Minimum flow: multistage pumps overheat if run against a closed valve (dead-headed) — fit a minimum-flow bypass or thermal protection on circuits that may run with all outlets shut.