Description
The Calpeda MÈTA pressure booster is a plug-and-play, variable-speed freshwater pressure system for yachts and superyachts — AISI 304 stainless wetted parts, an integrated variable-speed drive and Bluetooth monitoring.
Calpeda MÈTA Pressure Booster — Calpeda MÈTA — Variable Speed Freshwater Pressure System
The MÈTA is Calpeda’s most advanced domestic water pressure solution. All wetted components are AISI 304 stainless steel (casing, stage casing, impeller, cover) with AISI 303 shaft and carbon/ceramic/NBR mechanical seal — fully compatible with potable freshwater and domestic water supply systems.
How It Works
The integrated variable speed drive (VSD) continuously adjusts motor speed to match instantaneous demand, maintaining a constant delivery pressure regardless of how many outlets are open. There is no pressure switch hunting, no pressure vessel waterlogging, and no wasted energy running at full speed under low demand. The factory-set pressure is 3.5 bar, adjustable from 1.8 to 5.0 bar via the onboard control panel or Calpeda Flow app.
Choose Your Configuration
- MÈTA SMALL-2 — Single Pump: 0.65 kW, up to 4 m³/h (67 L/min), max head 55 m. Suited to sailing yachts and small motor yachts 10–25 m with up to 3–4 en-suite bathrooms.
- MÈTA-2 — Single Pump: 1.0 kW, up to 7 m³/h (117 L/min), max head 53 m. Suited to motor yachts 25–40 m with up to 5–6 en-suite bathrooms.
- BSM2V 2 MÈTA SMALL-2 — Twin Set: 2 × 0.65 kW on a common AISI 304 manifold. Up to 8 m³/h combined. Full duty/standby redundancy. G2 suction, G1½ delivery. For charter or commercial vessels 15–28 m.
- BSM2V 2 MÈTA-2 — Twin Set: 2 × 1.0 kW on a common AISI 304 manifold. Up to 14 m³/h combined. Full duty/standby redundancy. G2 suction, G1½ delivery. For superyachts 30–45 m or any vessel where continuous water pressure is mission-critical.
Key Specifications
- Supply voltage: Single-phase 220–240 V, 50 Hz
- Maximum liquid temperature: 35°C (cold freshwater supply only)
- Maximum working pressure: 8 bar
- Pressure setpoint: 1.8–5.0 bar (factory: 3.5 bar)
- Ambient temperature: up to 40°C
- Protection class: IPX4
- Connections (single unit): G1 suction and delivery
- Connections (twin set): G2 suction, G1½ delivery
Self-Priming Capability
Unlike most multi-stage pump systems which require flooded suction, the MÈTA incorporates a built-in backflow preventer that allows it to self-prime and maintain prime between cycles. The pump can be installed up to 3 m above the water source — a significant advantage on vessels where the pump cannot be positioned below the tank. On initial start, ensure the pump casing is filled with water.
Protections
Dry-run protection, air-in-casing detection, overload and overheating control, pump blockage, power supply monitoring, start-frequency limiter, small-leakage detection.
Duty Cycle
The MÈTA is rated for continuous duty (S1) — the motor can run at full load indefinitely without overheating, and is designed to run whenever demand is present. Maximum 90 starts per hour at regular intervals. The inverter monitors start frequency and will block operation if 150 starts are exceeded in one hour (manual reset required) — on a well-commissioned system with correct pressure vessel sizing this limit will not be reached under normal vessel use.
Dry-run protection: If installed in suction-lift mode, fit a float switch in the tank set to cut the pump when the water level drops below 0.5 m above the suction pipe centreline. The MÈTA has built-in dry-run detection, but the float switch provides an upstream failsafe that protects both the pump and the tank.
Important Notes
The MÈTA operates on single-phase 230 V only and is designed for cold freshwater supply (max 35°C). It is not suitable for raw seawater, hot water return circuits, or three-phase electrical systems. For hot water recirculation, pair with a Calpeda NCE ES bronze circulator. For yachts with three-phase 400 V systems or flow demands above 14 m³/h, see the Calpeda BS.MXV range.
Calpeda Flow App
Bluetooth connection (standard) or optional WiFi-BOX for remote access. Monitor delivery pressure, operating frequency, current draw, power input and voltage in real time. Adjust the pressure setpoint, review fault history and communicate data directly to the Y3 Marine service team for remote diagnostics.
Installation Requirements
The MÈTA is a self-priming pump and can be installed in two configurations:
- Flooded suction (recommended): Pump installed at or below the freshwater tank outlet. Water feeds the pump under gravity — the most reliable arrangement and the preferred installation on vessels.
- Suction lift: Pump installed above the tank outlet. Maximum suction lift is 3 m between the tank suction point and the pump centreline. Beyond 3 m the pump cannot reliably prime.
Suction pipe requirements: The suction pipe must be completely airtight — any air ingestion at fittings or joints will prevent priming and trigger the air-detection fault. Use rigid pipe where possible; if flexible hose is used, ensure it is rated for suction duty and will not collapse under negative pressure. Pipe bore must be no less than 1" (G1) throughout.