Description
The Calpeda BNG jet pump is a self-priming bronze pump for marine freshwater supply, ballast transfer and deck wash — a corrosion-resistant bronze casing with self-priming lift and up to 95 m head.
Calpeda BNG Jet Pump — Key Specifications
| Model | Max Head | Max Flow | Power | Suction | Delivery |
|---|---|---|---|---|---|
| BNG 3 | 52.1 m | 4 m³/h | 0.55 kW | G1 (1″ BSPP) | G1 (1″ BSPP) |
| BNG 4 | 45.8 m | 4.5 m³/h | 0.75 kW | G1 (1″ BSPP) | G1 (1″ BSPP) |
| BNG 5/16 | 64 m | 4.5 m³/h | 1.1 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| BNG 5/18 | 53 m | 6 m³/h | 1.1 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| BNG 5/22 | 36.5 m | 9.5 m³/h | 1.1 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| BNG 6/18 | 67.3 m | 6.5 m³/h | 1.5 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| BNG 6/22 | 53 m | 9.5 m³/h | 1.5 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| BNG 7/16 | 95 m | 5 m³/h | 2.2 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| BNG 7/18 | 77 m | 7 m³/h | 2.2 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
| BNG 7/22 | 60 m | 9.5 m³/h | 2.2 kW | G1½ (1½″ BSPP) | G1 (1″ BSPP) |
All figures at rated speed (~2900 rpm), 20°C water. BNG 7 series three-phase only.
Construction & Materials
The BNG series uses bronze (CC480K EN 1982) for the pump casing, casing cover and diffuser plate — the correct choice for marine environments where cast iron would corrode in the presence of salt air and moisture. The impeller is brass (CW617N EN 12167) throughout the range. The shaft is AISI 430F stainless steel on BNG 3 and 4; AISI 316 stainless steel on BNG 5 through 7. Mechanical seal is carbon/ceramic/NBR. The pump is close-coupled to an IEC standard motor, keeping the overall footprint compact and motor replacement straightforward.
The built-in ejector (Venturi body) creates a recirculation loop that allows the pump to evacuate air from the suction pipe at start-up, achieving self-priming even with the pump installed above the water source.
Applications
The BNG’s ejector design handles water containing entrained air or gas — useful where supply tanks may run low, suction lines are long, or the pump must start against a partially empty suction pipe. Typical marine uses include:
- Freshwater pressure and distribution
- Ballast transfer
- Deck wash
- Transfer from sumps or low-level holding tanks
- Bilge duty on clean-water systems (note: liquid temp limit 40°C)
BNG vs NGX — Which to Choose?
The BNG and NGX are mechanically identical self-priming jet pumps — same ejector design, same performance envelope, same motor options. The difference is entirely in the casing material, which affects cost, weight, temperature rating, pressure rating, and the size of pump available.
| BNG (Bronze) | NGX (Stainless Steel) | |
|---|---|---|
| Casing | Bronze CC480K | AISI 304 stainless steel |
| Max liquid temp | 40°C | 35°C |
| Max pressure | 10 bar | 8 bar |
| Largest model | BNG 7/22 (2.2 kW, 95 m max head) | NGX 6/22 (1.5 kW, 58 m max head) |
| Weight | 21–38 kg (heavier) | 8–18 kg (lighter) |
| Cost | Higher | Lower |
| Best for | Higher pressure/temp, larger duties, long service life | Weight-sensitive installs, cold freshwater, modest duties |
Choose BNG if: you need the larger BNG 7 series, require 10 bar system pressure, expect liquid temperatures above 35°C, or want the proven longevity of bronze in a salt-air engine room.
Choose NGX if: weight is a priority, your duty point sits within the NGX range, and liquid temperature stays below 35°C.
Protection & Standards
Motor enclosure IP54 (splash-proof). Insulation class F. Three-phase motors IE3 efficiency class (IE2 for motors up to 0.65 kW); single-phase motors IE2 up to 1.1 kW. Built to EN 60034-1, EN 60335-1, EN 60335-2-41. CE marked. Maximum starts per hour: 40 at regular intervals.
Duty Cycle
Three-phase models (BNG) are rated S1 — continuous duty: the pump can run indefinitely at rated load without a rest period. Single-phase models (BNGM) up to 1.5 kW are rated S3 60% — intermittent duty: 6 minutes running followed by 4 minutes rest per 10-minute cycle. For high-cycle or continuously running applications, specify the three-phase variant.
Important Notes
- BNG is the bronze marine-grade version. Cast iron (NG) available on request for non-marine applications.
- Single-phase (BNGM) available for BNG 3 through BNG 6/22. BNG 7 series is three-phase only.
- Three-phase motors: 230/400V ±10%. Single-phase motors: 230V ±10%.
- A non-return (foot) valve on the suction line is strongly recommended to retain prime between starts.
- Pump must be filled with water before first start.
- Liquid temperature limited to 40°C.
Installation Requirements
The BNG is designed for horizontal installation with the motor shaft horizontal and support feet facing down. Install as close as possible to the water source to minimise suction pipe losses. The suction pipe must be completely airtight — any air ingress reduces self-priming performance. A foot valve or non-return valve at the base of the suction pipe retains the water column after shutdown and shortens re-priming time on restart. Before first start, fill the pump body completely with clean water through the priming port. For three-phase connection, verify rotation direction matches the arrow on the pump housing. Provide isolation valves on suction and delivery for servicing access. Allow adequate clearance around the motor for ventilation.
Engineering & Selection Notes
- Reading the table: max flow and max head are curve endpoints — max flow occurs near zero head and max head near zero flow. The real duty sits on the curve between them, ideally near the best-efficiency point; Y3 Marine selects to your duty point.
- Engine-room ambient: motor ratings assume ≤40 °C ambient; engine rooms often run hotter, so above 40 °C de-rate the motor or step up a frame size to avoid thermal overload.