Calpeda B-A Self-Priming Bronze Pump

Calpeda B-A marine-grade bronze self-priming centrifugal pump. Handles solids up to 15 mm. Ideal for bilge dewatering, grey and black water transfer, fire pump duty, and anchor wash. Available in four frame sizes: A 40-110 to A 80-170. Three-phase and single-phase supply options available. Sourced to order via Calpeda Australia.

Add to Quote
SKU: N/A Category: Tag:

Description

The Calpeda B-A self-priming pump is a bronze close-coupled centrifugal pump for bilge dewatering, grey- and black-water transfer, fire-pump duty and anchor wash aboard superyachts and commercial vessels.

The Calpeda B-A Self-Priming Bronze Pump is a close-coupled centrifugal pump built for the demanding transfer and dewatering duties found aboard superyachts and commercial vessels. With a bronze CC480K casing, AISI 316 stainless shaft, and open impeller capable of handling solids up to 15 mm, the B-A is the pump of choice for bilge dewatering, grey and black water holding tank transfer, anchor wash systems, and fire pump applications where self-priming capability is non-negotiable. The integral backflow preventer prevents reverse siphoning on shutdown and ensures the pump re-primes automatically at the next start — even from a completely empty suction pipe.

Calpeda B-A Self-Priming Pump — Key Specifications

Model Connections (In/Out) Power Range Max Head Max Flow Max Pressure Solids Weight (BA)
A 40-110 G1½ / G1½ 0.55 – 0.75 kW 17.2 m 18 m³/h 6 bar 10 mm 21.6 – 23.3 kg
A 50-125 G2 / G2 0.75 – 1.5 kW 20.5 m 33 m³/h 6 bar 10 mm 31.2 – 35.0 kg
A 65-150 G2½ / G2½ 2.2 – 4 kW 30.8 m 57 m³/h 6 bar 15 mm 52.5 – 63.2 kg
A 80-170 G3 / G3 5.5 – 7.5 kW 35 m 66 m³/h 10 bar 15 mm 89.9 – 95.1 kg

Sized to the bilge code, not guesswork. The A 40 to A 65 frames (18–57 m³/h) map directly onto the class bilge-pump requirement: the NSCV/SOLAS bilge main is sized by d = 1.68√(L(B+D)) + 25 mm and the pump to give at least 2 m/s in it — roughly 14–37 m³/h for vessels of 25–65 m. The A 80-170 (66 m³/h, 10 bar) covers fire-main and emergency-salvage duty. Y3 Marine matches the frame to your vessel’s bilge and fire requirements.

Construction & Materials

  • Pump casing, impeller & lantern bracket: Bronze CC480K (EN 1982) — marine-grade corrosion resistance for bilge and saltwater-contaminated service
  • Shaft: AISI 316 stainless steel (1.4401) on B-A variant — superior corrosion resistance
  • Mechanical seal: Carbon / Ceramic / NBR — suitable for grey water, black water, bilge, and clean water service
  • Open impeller design: handles suspended solids up to 10 mm (A 40, A 50) or 15 mm (A 65, A 80) without blockage
  • Integral backflow preventer: prevents reverse siphoning on shutdown; ensures automatic re-prime at next start even from a fully empty suction pipe
  • Liquid temperature range: −10°C to +90°C
  • Ambient temperature: up to 40°C
  • 2-pole induction motor, 50 Hz: approx. 2,900 rpm
  • Motor insulation: Class F
  • Motor protection: IP54 as standard; IP55 available on request
  • Efficiency class: IE3 (three-phase from 0.75 kW); IE2 (single-phase up to 1.1 kW)

Applications

  • Bilge dewatering: Self-priming capability is essential for bilge duty — the B-A re-primes automatically when bilge levels drop and recover, without manual intervention. Solids handling tolerates debris, residue, and light sediment typical in vessel bilges.
  • Grey water holding tank transfer: Transfers accumulated grey water from holding tanks to a sewage treatment plant, deck discharge connection, or overboard discharge fitting. The self-priming design allows the pump to be mounted above the tank and start against a partially or fully empty suction line.
  • Black water holding tank transfer: Transfers sewage holding tank contents to an onboard sewage treatment plant, deck discharge for shore reception, or an approved marine sanitation device (MSD). Solids handling capacity accommodates partially treated or lightly macerated waste. Confirm impeller clearance against particle size for the specific MSD or tank arrangement.
  • Fire pump and emergency dewatering: The B-A series is capable of delivering to fire mains and emergency salvage lines. The pump must be sized to meet the required fire main pressure and simultaneous flow demand for the vessel class. Flag state, classification society, and coastal state requirements apply — consult Y3 Marine for sizing and compliance guidance.
  • Anchor wash and deck wash: The A 40-110 and A 50-125 are well suited to anchor chain wash-down and general deck wash systems where moderate flow and head are required.

Why Y3 Marine Stocks the B-A Bronze Variant

Calpeda produces the A series in both cast iron (A) and marine-grade bronze (B-A). For superyacht and commercial vessel service — where bilge water is saltwater-contaminated and waste systems are in constant contact with corrosive liquids — the cast iron variant is not appropriate. Y3 Marine sources the B-A bronze build as standard. Bronze CC480K provides the corrosion resistance required for long-term service in bilge, grey water, and black water applications. The B-A is sourced to order via Calpeda Australia; contact us to confirm availability and lead time.

Protection & Standards

  • IP54 standard; IP55 on request
  • Constructed in accordance with EN 60034-1, EN 60034-30-1, EN 60335-1, EN 60335-2-41
  • Tolerances per UNI EN ISO 9906:2012

Duty Cycle

  • Three-phase motors: S1 continuous duty
  • Single-phase motors (up to 1.5 kW): S3 60% intermittent duty — suitable for bilge and wash-down duties that are inherently intermittent

Important Notes

  • Single-phase (AM) supply is available for A 40-110 and A 50-125 only. A 65-150 and A 80-170 are three-phase only.
  • Maximum working pressure is 6 bar for A 40, A 50, and A 65 models; 10 bar for A 80-170.
  • For fire pump duty: the pump must be sized to meet vessel-specific fire main flow and pressure requirements. Flag state and classification society approval may be required. Contact Y3 Marine before specifying for fire service.
  • For black water service, confirm impeller clearance is adequate for the particle size after maceration.
  • Other voltages, 60 Hz supply, and special mechanical seals are available on request.

Installation Requirements

  • BSP (ISO 228) threaded connections: G1½ (A 40), G2 (A 50), G2½ (A 65), G3 (A 80)
  • Close-coupled design; motor and pump share a single shaft — no alignment required
  • Suction pipe should be as short as practical and installed with a rising gradient to the pump to aid priming. A foot valve is recommended where suction lift exceeds 4 m.
  • Single-phase models include integral thermal protector and capacitor inside the terminal box
  • Three-phase wiring: 230/400V up to 3 kW; 400/690V from 4 to 7.5 kW

Engineering & Selection Notes

  • Reading the table: max flow and max head are curve endpoints — max flow occurs near zero head and max head near zero flow. The real duty sits on the curve between them, ideally near the best-efficiency point; Y3 Marine selects to your duty point.
  • Engine-room ambient: motor ratings assume ≤40 °C ambient; engine rooms often run hotter, so above 40 °C de-rate the motor or step up a frame size to avoid thermal overload.
  • Generator starting: direct-on-line start draws ~6–8× full-load current — on larger three-phase motors use star-delta, soft-start or a VSD and check inrush against available generator capacity.

Additional information

Model

A 40-110, A 50-125, A 65-150, A 80-170

Motor Supply

Three-phase, Single-phase

Brand

Calpeda

Casing Material

Bronze CC480K

Impeller Type

Open impeller

Pump Type

Self-priming centrifugal

Max Liquid Temperature

90°C

Max Working Pressure

6 bar (10 bar: A 80-170)

Solids Handling

Up to 10 mm (A 40/50), up to 15 mm (A 65/80)

Motor Protection

IP54

Shaft Material

AISI 316 stainless steel

Frequency

50 Hz

Brand

Calpeda

We respond to the different requirements for optimal integrated water cycle management